您好,欢迎光临济南金力升降机械有限公司官方网站!
24小时服务热线:18766191320

24小时服务热线

18766191320

山东升降机10个安全操作的步骤

来源:http://www.jlsjj.cn     发布时间:2021-12-01   浏览次数:

建筑升降机应为人货两用升降机,其安装、拆卸工作必须由经训练并取得操证的人员负责,其安装、拆卸工作必须由经训练并取得操证的人员负责。
The building lift should be a dual-purpose lift, and its installation and disassembly must be undertaken by professional personnel who have received professional training and obtained a certificate of operation, the installation and disassembly work must be undertaken by professional personnel who have received professional training and obtained operating license. 
检查项目应符合以下要求:
 Key inspection items shall meet the following requirements: 
步骤1:各部分结构无变形,边接螺栓无松动;
Step 1: All parts of the structure without deformation, no loosening of the side bolts;
步骤2:齿条、齿轮、导轮和导轨都是正常连接的;
 step 2: Rack, gear, guide wheel and guide rail are normally connected; all parts of the wire rope fixed well, no abnormal wear;
各部分钢丝绳固定良好,无异常常磨损;
All parts of the wire rope fixed well, no abnormal wear;
步骤3:操作范围无障碍。
山东升降机起动前,应检查并确认电缆、地线是否完好无缺,控制开关在零位。
电缆线通电后,检查电压是否正常,检测无漏电现象。测试确认各限位装置、梯笼、门锁等电器连结装置性能良好、可靠性高,电器灵敏有效。
起动后,山东升降机进行空载提升试验,确定各传动机构制动器的效能,确认正常后,方可开始工作。
Step 3: Accessibility. Shandong lift before starting, should check and ensure that the cable, ground wire is intact, control switch at zero. 
步骤4:升降机在每班载重运行时,当梯笼升离地面1~2m时,应停机试验制动器的可靠性;当发现制动效果不良时,应调整或修复后方可运行。
Step 4: Lift in the first load operation of each shift, when the cage lift off the ground 1 ~ 2 m, should stop test the reliability of the brake; when found poor braking effect, should be adjusted or repair after operation.  out, the end of the motor brake electromagnet manual release pull out slowly, so that the cage slowly slide downward. When the ladder cage slides down, must not exceed the rated operating speed, the manual descent must be operated by professional maintenance personnel.
步骤5:梯笼内乘人或载物时,应使载荷均匀分布,不得偏重。严禁超载运行。
Step 5: Ladder cage passengers or load, should make load uniform distribution, not too heavy. Overload operation is strictly prohibited. 
步骤6:操作人员应根据指挥信号操作。作业前应鸣声示意。在升降机未切断总电源开关前,操作人员不得离开操作岗位。
Step 6: The operator should operate according to the command signal. Sound the signal before work. The operator shall not leave the operating position before the main power switch is cut off. 
步骤7:当升降机运行中发现有异常情况时,应立即停机采取有效措施将梯笼降到底层,排除故障后方可继续运行。
在运行中发现电气失控时,应立即按下急停按钮;在未排除故障前,不得打开急廷按钮。
Step 7: When the elevator operation found abnormal circumstances, should immediately stop to take effective measures to lower the cage to the bottom, after troubleshooting can continue to run. If the electric system is out of control, the emergency stop button should be pressed immediately, and the emergency stop button should not be opened before the fault is removed. 
步骤8:升降机在大雨、大雾、六级及以上大风以及导轨架、电缆等结冰时,必须停止运行,并将梯笼降到底层,切断电源。
Step 8: Lift in heavy rain, fog, six or more gale and guide rail frame, cable and other ice, must stop running, and the cage down to the bottom, cut off the power.
暴风雨后,应对山东升降机各有关安全装置进行一次检查,确认正常后,方可运行。
 After the storm, the Shandong lift should be related to the safety device for an inspection, confirmation of normal, before the operation. 
步骤9:升降机到更上层或更下层时,严禁用行程限位开关作为停止运行的控制开关。
tep 9: lift to the top or bottom, the trip limit switch is strictly prohibited as the Stop Operation of the control switch. Step 10: When the lift is stopped in operation due to power failure or other reasons, manual descent can be carried
步骤10:当升降机在运行中由于断电或其它原因而中途停止时,可进行手动下降,将电动机尾端制动电磁铁手动释放拉手缓慢向外拉出,使梯笼缓慢地向下滑行。
Step 10: When the lift is stopped in operation due to power failure or other reasons, manual descent can be carried out, the end of the motor brake electromagnet manual release pull out slowly, so that the cage slowly slide downward. 
梯笼下滑时,不得超过额定运行速度,手动下降必须由维修人员进行操纵。
When the ladder cage slides down, must not exceed the rated operating speed, the manual descent must be operated by professional maintenance personnel.

上一篇:一篇文章使您对建筑电梯有了一个全面的了解